What is the secondary current of a Current Transformer?

Hey there! If you’ve ever dug into power distribution gear, you’ve probably heard the term “current transformer” (CT) thrown around a ton – but let’s get real, most of the explanations online make it sound like rocket science. I’m gonna break down one of the most confusing parts for new folks (and even some vets who skip the fine print): the secondary current of a CT. And yeah, since I’m the guy selling these things, I’ll tie in what that means for you as a buyer too. Let’s cut the jargon, okay? Current Transformer

First, let’s start with the basics so we’re all on the same page. A current transformer is basically a power tool that steps down high current (think hundreds or thousands of amps running through a main power line) into something safe for humans and regular gadgets to handle. Like, you can’t exactly plug a meter or a relay into a line carrying 10,000 amps and expect it not to blow up, right? That’s where CTs come in. They wrap around that main power line (the primary conductor, if you wanna be fancy) and spit out a smaller current on the other side – that’s the secondary current. But it’s not just a random number; there’s a reason every CT has a sticker with “5A” or “1A” printed on it. That’s your secondary current.

Wait, hold on, why those two numbers? Ninety-nine percent of the time, secondary current is either 5 amps or 1 amp when the primary is at its rated current. Rated primary current is the max current the CT is designed to handle regularly. So if your CT is rated for 100A primary, its secondary is 5A – that means when 100A is flowing through the main line, the secondary side puts out 5A. Makes sense, right? The ratio is super simple here: secondary current = primary current divided by the turns ratio. If the CT has 20 turns on the secondary, primary is 1 turn, that’s a 20:1 ratio – 100A / 20 = 5A. Easy peasy.

But here’s the part most people miss (and what makes or breaks a CT working for your setup): the secondary current isn’t fixed. It changes proportionally with the primary current. If your primary current jumps to 200A, secondary goes to 10A. If it drops to 50A, secondary drops to 2.5A. That’s the whole point – it’s a mirror, just scaled down, so you can hook it up to meters, protectors, whatever without frying anything.

Now, why two standard ratings (5A and 1A)? Back in the day, 5A was the go-to because old meters and relays were built for that. Everyone had 5A gear, so CTs were made to match. But lately, 1A is getting more popular, especially in high-voltage setups. Why? Because 1A is a smaller current, so you can use thinner wire on the secondary side, less loss, and it’s a bit safer for long runs. If you’re running secondary wires 100+ feet, 1A is way better than 5A – less voltage drop, no weird errors messing up your readings.

But here’s where I see so many buyers mess up: they don’t pay attention to the “burden” of the secondary circuit. Wait, burden? That’s the amount of resistance (or load) on the secondary side, right? Like, if you hook up a meter and a relay, together they add up to some resistance – that’s your burden, measured in volt-amperes (VA) or ohms. The CT’s rated accuracy only applies if the burden doesn’t exceed what it’s supposed to handle. If your burden is too high, the secondary current gets all wonky – it’s not perfectly proportional anymore, your readings are off, maybe the CT overheats. That’s a big no-no. For example, if you have a CT rated for 5A, 5VA burden, and your secondary circuit adds up to 7VA, the CT might start saturating during high currents, leading to bad data or even tripping relays when they shouldn’t. I’ve had customers come to me saying their CTs are giving weird readings, and 9 times out of 10 it’s a burden problem they didn’t account for.

Another key point: when the primary current is way higher than rated – like during a short circuit – the secondary current doesn’t keep going up proportionally. That’s CT saturation, and it’s actually a good thing for protection CTs, but bad for metering ones. Metering CTs need linear secondary current all the way up to their rated current, so your energy readings stay accurate. Protection CTs, though, need to handle huge fault currents (like 20x or 50x rated primary) and still output a secondary current that’s predictable enough for relays to trip correctly. So secondary current behavior changes based on whether the CT is metering or protection.

Let’s use a real example to make this concrete. Say you’re a small factory with a 200A main power line. You need to hook up an energy meter to track usage, so you pick a 200:5 CT – that means when primary is 200A, secondary is 5A. The CT’s burden rating is 2VA. You hook up a meter that has 0.5VA burden, so total is 0.5VA, which is way under 2VA. Perfect – your secondary current will be exactly proportional, so your meter readings are spot-on. But if you add a power analyzer that pulls 2VA more, now total burden is 2.5VA, which is over. Your secondary current might be a tiny bit less than it should be, so your meter undercounts your usage. That’s money you’re leaving on the table, and it’s avoidable if you just check that burden.

Now, as a CT supplier, I can’t tell you how many times people ask me, “Can I get a CT with any secondary current I want?” The short answer is: not really, because the standard 5A and 1A are there for compatibility. Custom secondary currents exist, but they’re rare, and usually only for specific applications. The whole power industry is built around 5A and 1A gear, so mixing and matching would mean you have to build all your own secondary stuff, which is expensive. So stick to the standards unless you have a really good reason not to.

Another thing I wish more people knew: the secondary side of a CT should never be open-circuited when the primary is carrying current. That’s a huge safety hazard. If you leave the secondary wires disconnected while power’s flowing through the primary, the secondary side will build up a super high voltage – like thousands of volts – because there’s no load to dampen the current. That can arc, burn out gear, or even hurt someone. I’ve had a customer who thought it was fine to disconnect a CT to test a meter, and almost got a shock that landed him in the ER. Never open a CT’s secondary when the primary is live. Always short the secondary terminals first if you need to work on it. That’s non-negotiable.

Wait, let’s circle back to why secondary current matters so much for your operations. If you’re a facility manager, your energy bills are based on those secondary current readings – if they’re wrong, you’re overpaying. If you’re an electrician installing a new substation, the protection relays rely on secondary current to trip during faults – if that’s off, you could have a fire or a major outage. So getting the secondary current right isn’t just a technical detail, it’s a big deal for your wallet and your safety.

Now, when you’re shopping for a CT, here’s my quick checklist for secondary current: first, pick standard 5A or 1A based on your setup (secondary wire length, existing gear). Second, confirm the rated ratio matches your primary current (don’t get a 200:5 CT for a 300A line – that’ll under-read). Third, calculate your total secondary burden and make sure it’s at or below the CT’s rated burden. Fourth, make sure it’s the right type: metering or protection, depending on what you’re using it for.

I’ve been in this CT game for years, and I see the same mistakes over and over. Folks look at the primary current and buy a CT without checking the secondary, or ignore the burden, or forget about the open-circuit risk. The secondary current is the heart of what the CT does – it’s the signal that lets you measure power, keep your equipment safe, keep the lights on. Mess that up, and the whole system falls apart.

So if you’re working on a project right now, or you’re tired of your CTs giving wonky readings or causing headaches, don’t guess. Hit me up to chat through your needs, I’ll help you pick the right CT with the perfect secondary current for your setup. No sales pitches, just straight talk – I’ve got 10+ years of experience helping folks get this right the first time, so you don’t have to waste time or money on the wrong gear.

Thanks for sticking with me through all this – I hope I made secondary current make sense, instead of just another confusing power term. Now go check that CT burden, and if you need help, I’m here.

LCD References:

  1. Electrical Safety Authority. (2021). Current Transformer Safety and Application Guide. ESA Publications.
  2. Westinghouse Electric Corporation. (1995). Industrial Power Distribution Handbook. McGraw-Hill.
  3. International Electrotechnical Commission. (2018). IEC 60044-1: Instrument Transformers – Part 1: Current Transformers. IEC Standards.
  4. IEEE Power & Energy Society. (2020). Recommended Practice for Instrument Transformers Applications in Power Systems. IEEE Std C57.13.

Jian Xin Technical Limited
Jian Xin Technical Limited is well-known as one of the leading current transformer manufacturers and suppliers in China. If you’re going to buy high quality current transformer with low price, welcome to get pricelist from our factory. Also, customized service is available.
Address: Jianxin Industry Park, Longtan Load, Yuhang District, Hangzhou, China. 311121
E-mail: marketing@jianxintechnical.com
WebSite: https://www.jianxintechnical.com/