What are the common faults of a discharge coil?

If you’re working in high-voltage electrical systems, you know how critical discharge coils are to managing fault currents, protecting equipment, and maintaining grid stability. As a discharge coil supplier with years of hands-on experience troubleshooting field issues and supporting clients, I’ve seen firsthand that even a seemingly minor fault in these components can lead to costly downtime, safety hazards, or widespread power outages. In this post, I’ll break down the most common discharge coil faults we encounter, explain their root causes, and share practical insights that can help operators and maintenance teams identify and address issues before they escalate. Discharge Coil

First, let’s start with a quick refresher on what a discharge coil does. Also known as a grounding reactor or surge diverter, a discharge coil is a low-inductance device connected between a neutral point and ground in high-voltage distribution and transmission networks. Its primary role is to limit the magnitude of earth fault currents, suppress transient overvoltages, and provide a path for fault current to flow safely to ground during a fault event. When this component fails, the entire system’s fault protection mechanism is compromised—making it essential to spot faults early.

One of the most prevalent faults we see is insulation degradation, often caused by prolonged exposure to environmental stressors. Discharge coils are typically installed outdoors in substations, power plants, or overhead line yards, where they face extreme temperatures, humidity, dust, and occasional moisture intrusion. Over time, these factors break down the insulating materials—usually epoxy resin, paper, or varnish—that separate the coil’s windings from each other and the metal core. For example, a client in the Midwest recently contacted us after their 138kV discharge coil failed an insulation resistance test. Upon inspection, we found that moisture had seeped into the coil’s housing through a small crack in the silicone rubber coating, causing the insulation resistance to drop from the required 10,000 megohms to just 200 megohms. This degradation creates a path for leakage current, which not only reduces the coil’s effectiveness during faults but can also lead to winding short circuits. We’ve also noticed that thermal cycling plays a role here: when the coil heats up during normal operation and cools down when the system is inactive, the insulating materials expand and contract, leading to microcracks that accelerate moisture ingress.

Another common fault is core saturation and excessive core loss. Discharge coils are designed to operate in a linear inductance range under normal load conditions, but if subjected to overvoltages or prolonged overcurrent events, their core can saturate. Saturation occurs when the magnetic core material (usually laminated silicon steel) reaches its maximum flux density, causing the coil’s inductance to drop sharply. This undermines the coil’s core function of limiting earth fault currents—during a ground fault, the reduced inductance lets fault currents spike beyond safe limits, damaging connected equipment like transformers or circuit breakers. We’ve seen this happen in systems where surge arresters fail to divert transient overvoltages, forcing the discharge coil to absorb excess energy repeatedly. A regional utility client reported that two of their 69kV discharge coils had failed due to core saturation after a nearby lightning strike caused a series of transient overvoltages. The coils had operated beyond their voltage rating for an extended period, leading to irreversible core damage and a 30% increase in core loss, which in turn caused the coil to overheat and burn out one winding. Excessive core loss also leads to overheating, which can further degrade insulation and create a vicious cycle of failure.

Winding faults, including open circuits and short circuits, are also a top issue for discharge coils. An open circuit in the winding can occur due to mechanical stress—for example, when the coil is subjected to strong magnetic forces during a fault event, or during installation if the winding is pulled too tightly. We once supported a client that had a discharge coil fail during a temporary ground fault test: the intense magnetic force bent one of the coil’s winding leads, causing a complete open circuit. Without a functional discharge coil, the fault current flowed unchecked, damaging two downstream transformers and costing the client over $150,000 in repairs and lost production. Short circuits, on the other hand, can be turn-to-turn or winding-to-core, usually caused by insulation breakdown. Turn-to-turn shorts are particularly insidious because they don’t always trigger an immediate failure—instead, they gradually reduce the coil’s effective inductance, making it less effective at limiting fault currents. Over time, these shorts can concentrate current in a small section of the winding, leading to localized overheating and eventual burnout. We recommend regular thermal imaging scans to detect hotspots caused by winding shorts before they cause a full failure.

Ground connection faults are another often-overlooked but critical issue. The discharge coil’s ground terminal must be securely connected to a low-resistance earth electrode (typically 5 ohms or less, per industry standards) to function properly. If the ground connection becomes loose, corroded, or has high resistance, the coil cannot provide a safe path for fault current to flow to ground. This leads to fault current being diverted through unintended paths, such as adjacent equipment or personnel—creating a serious safety hazard. We recently worked with a substation operator that discovered a ground connection fault during routine maintenance: years of exposure to rain and salt had corroded the copper grounding lug, increasing the ground resistance from 3 ohms to over 200 ohms. During a minor ground fault test, the fault current arced across the corroded connection, damaging the coil’s terminal and nearly causing a fire. Ground connection faults are easy to miss because they don’t always trigger alarms, so we advise our clients to include ground resistance testing as part of their quarterly maintenance schedule.

Finally, aging and component wear are unavoidable faults in discharge coils, especially in systems that have been in operation for 20+ years. Over time, all the coil’s components—windings, core, insulation, and terminals—degrade, even if the system is well-maintained. For older coils, we often see a combination of multiple faults: insulation that has become brittle and cracked, core that has lost its magnetic properties, and terminals that are corroded. A utility in the Northeast recently replaced four 230kV discharge coils that had been in service for 25 years. Testing revealed that all four coils had insulation resistance below the acceptable limit, three had core loss rates double the original specification, and two had partial winding shorts. In these cases, repairing the coil is rarely cost-effective—replacing it with a modern, properly rated discharge coil is the only reliable solution. As a supplier, we often advise clients to audit their discharge coils every 10 years, or after any major system event, to catch aging-related faults early.

Now, let’s talk about how to prevent these common faults. First, follow proper installation practices: ensure the coil is rated for your system’s voltage and fault current, use high-quality insulating materials, and secure all connections tightly. Second, implement a regular maintenance schedule: test insulation resistance quarterly, check ground connections monthly, perform thermal imaging annually, and inspect for physical damage (like cracks in the housing) after severe weather events. Third, use surge protection devices alongside discharge coils to reduce the number of transient overvoltages the coil is exposed to. Finally, for older systems, consider upgrading to modern discharge coils that feature advanced insulation materials (like cross-linked polyethylene) and corrosion-resistant terminals, which have a longer service life and better performance.

At our company, we’ve spent decades designing and manufacturing discharge coils tailored to meet the specific needs of high-voltage systems. Our team of engineers works closely with clients to assess their fault protection requirements, select the right coil rating, and provide ongoing support to troubleshoot any issues that arise. If you’re experiencing discharge coil faults in your system, or if you’re planning to upgrade your fault protection equipment, we’re here to help. Our experts can conduct on-site inspections, perform diagnostic testing, and recommend solutions that align with your budget and operational needs. Don’t wait for a costly outage—reach out to our team today to discuss your discharge coil requirements and find the right solution for your system.

Distribution Transformer References

  1. IEEE Std C37.122-2017, IEEE Standard for Gas-Insulated Substations
  2. NEMA Standard SG-6, Standards for Grounding Reactors for AC Power Systems
  3. Electrical Construction and Maintenance Magazine, “Understanding Discharge Coil Failures in High-Voltage Grids”, 2022
  4. Transformer Technology Corporation, “Field Maintenance Practices for Discharge Coils”, 2021
  5. International Electrotechnical Commission (IEC) Standard 60076-6, Power Transformers – Inductors